Guyed Wire Communication Tower is an important part of modern communication infrastructure and plays a vital role in providing reliable and efficient communication services.

Single Circuit Transmission Line refers to an arrangement of conductor over the Transmission Tower. In Single Circuit Transmission Line, three conductors corresponding to three distinct phases i.e. R, Y & B phase are run on the Transmission Tower.Double Circuit Transmission Line refers to the arrangement in which a total of six conductors are provided to make two different Transmission Circuit. In Double Circuit Transmission Line, there are two circuits each consisting of three conductors corresponding to three phases.

Both the circuits in Double Circuit Transmission Line are mounted or run through the same Transmission Line. In Double Circuit Transmission Line, bundle conductors are mostly used.A general thumb rule is that, if the number of conductor per bundle is 2 then it will be 220 kV line while if the number of conductor per bundle is 4 then it will be 400 kV line. This is general thumb rule and variation is expected.

Power supply using Double Circuit Transmission Line enables the transfer of more power over a particular distance.  However, running two circuits in close proximity to each other will involve inductive coupling between the conductors.  This needs to be taken into account when calculating the fault level and while designing the protection schemes. In case of Distance Protection of Double Circuit Line, a compensation for Mutual Coupling between the circuits shall be provided otherwise the Distance Relay may under-reach / overreach.

Let us suppose that we have a Power Generating Station and we want to supply three phase power to load centre A through two different lines. In this case it will be advantageous and economical to use Double Circuit Transmission Line as the cost of extra Towers will be saved if we used Single Circuit Transmission Line. The transmission is thus cheaper and requires less land and is considered ideal from an ecological and aesthetic point of view.  Further, due to Double Circuit Transmission Line the reliability of power supply increases. Not only reliability rather maintenance opportunity also increases. If we want to take one circuit on maintenance then power supply through the other circuit will continue.

Voltage 10
Current 10
Place of Origin Qingdao,China
Material Q345B/A572, minimum yield strength >=345MPA;

Q235B/A36, minimum yield strength>=235MPA

Or according to the standards provided by the customer

Details & Shape Can be designed as per customer’s requirement
Good’s Description Cable and Ladder can be assembled by customer’s request
Lifetime 20 years
Main Pole Lifetime More than 20 years
Barks Hot Dip Galvanization or Painted
Delivery Time According to customer requirements
Galvanizing Standard EN ISO 1461,ASTM/A123 or equivalent
Working & Resting Platform Quantity 1-3 PCS
Antenna Support 3-18 PCS
Microwave Dish 3-18 PCS
Manufacturing and Workmanship BS449 or AISC or equivalent
Welding Standard AWS D1.1, AS554, AS 4100 standard or equivalent
Nuts& Bolts Grade 8.8
Spare parts All Necessary parts, e.g. Antenna Mount pole and Brackets , Climbing Steps, Safety Guide Cable, Lightning Rod, Mounting bracket for Obstruction light, Holding down bolts/nuts, and all other bolt and nuts required for erection and installation